Armin Akbarzadeh; Ehsan Fallah; Seyed Ali Hashemi; Seyed Mohammad Tahami; Babak Pourabbas; Saeed Solooki
Volume 11, Issue 2 , April 2023, , Pages 69-74
Abstract
Objective: This study aimed to evaluate the radiologic and clinical outcomes of TKA with non-stemmed tibial components in relation to their body mass index (BMI).Methods: In this retrospective cohort study, the outcome of TKA with non-stemmed tibial components based on their BMI was evaluated (BMI<30 ...
Read More
Objective: This study aimed to evaluate the radiologic and clinical outcomes of TKA with non-stemmed tibial components in relation to their body mass index (BMI).Methods: In this retrospective cohort study, the outcome of TKA with non-stemmed tibial components based on their BMI was evaluated (BMI<30 vs. BMI≥30). The patients’ function was assessed using the International Knee Documentation Committee (IKDC) and Lysholm knee questionnaires. Radiologic evaluation for probable signs of loosening was performed using two quantitative scoring systems by Ewald and Bach et al. Moreover, we reviewed the current literature on the application of non-stemmed tibial components in obese patients.Results: Twenty-one patients (two men and 19 women) with BMI≥30 and a mean age of 65.1±9.5 years, and 22 patients (three men and 19 women) with BMI<30 and a mean age of 63.6±8.5 years were studied. The mean follow-up periods with BMI≥30 (47.0±19.8 months) and BMI<30 (49.2±18.7 months) were comparable (p=0.618). No patients in either group experienced clinical loosening. Besides, none of the patients had any kind of revision surgery. The patients in both BMI groups had comparable IKDC scores (both the total score and its sub-scores; p>0.05). Furthermore, the total Lysholm knee scores were similar in both groups (p=0.122). Using both scoring systems, the peri-prosthetic bone radiolucency near the tibial components was similar in both groups (p>0.999).Conclusion: The present study found no significant difference in the radiologic or clinical outcome of unstemmed TKA in patients with BMIs under and over 30.
Ali Ghaemmaghami; Ehsan Fallah; Hamid Namazi; Mohammad Taghi Karimi; Seyed Iman Houseini
Volume 9, Issue 1 , January 2021, , Pages 9-14
Abstract
Objective: To compare the stability of the radius stabilized fractured parts by volar and dorsal planting based on modeling approach. Methods: Ten forearm models were created based on Computed Tomography (CT) Scan images by using of Mimics software. The distal part fracture of radius was induced in the ...
Read More
Objective: To compare the stability of the radius stabilized fractured parts by volar and dorsal planting based on modeling approach. Methods: Ten forearm models were created based on Computed Tomography (CT) Scan images by using of Mimics software. The distal part fracture of radius was induced in the models. The stress were developed and implanted in various parts of the bone and and their displacement were evaluated in volar and dorsal inserted implants. Results: The results of this study showed that the stress developed in screws, implant and bony parts differed significantly between volar and dorsal plate conditions. The displacement of implant and bony parts in volar plating was more than dorsal plating (p=0.05). However, the screws displacement in dorsal plating significantly increased compared to volar plating. Conclusion: The stress developed in dorsal and volar implants is not too high to fail the structure. However, it seems that the irritation of soft tissue and tendon would be less in volar inserted implant than dorsal implant. It is recommended to use valor plating to be a good approach for stabilizing the distal part fracture of radius.